Author 
russ b

06-14-2007 17:13:32




Report to Moderator

I have my 8n generator off. It has three wire connectors. I understand some only had one. As far as I can tell it should work. I would like to do some kind of bench test before putting it back on. I seem to recall that a generator is a sort of electric motor.

Should I be able to power it up and make it spin? All help appreciated

I have been using a charger for years, since I made feeble attempt years ago.

[Log in to Reply]   [No Email]
soundguy

06-14-2007 22:54:07




Report to Moderator
 Re: Generator in reply to russ b, 06-14-2007 17:13:32  
YES.. do a motor test.. most gennies that charge will motor.. most gennies that motor will charge. there ARE exceptions.

Get a battery.. preferably 6v.. though a 12v will do. get a set of jumper cables. get a jumper wire with gator clip ends. hook jumper cables to battery... hook positive cable to genny case ( might be easier to put genny in a vice with minimal pressure.. and then clamp p-jumper cable to vice ). Now hook neg cable up to armature.. which is the terminal by itself ont he back plate of the genny.

Now jumper the 2 side by side posts on the genny barrel. genny should motor.

By the way.. you just polarized it too. If it don't charge after that.. suspect the vr.. ( and post back )

soundguy

[Log in to Reply]  [No Email]
russ b

06-15-2007 10:28:36




Report to Moderator
 Re: Generator in reply to soundguy, 06-14-2007 22:54:07  
Sound Guy, Zane,

I hooked up to six volt in the sequence, +ground, -armature. It was at that point I was getting some light spaking, nothing more than noticable, as I connected to the back post.

Proceeding further, when I bridged the posts on the side of the barrel it commenced to turning. After I unbridged the two SPs it continued to turn, with just the -EP and + G. I only ran it for a few seconds.

It turned rather slowly300 rpm +/-

This is all very new and interesting to me. There is the slow-fast adjuster that is still functional, humm...

Thanks for your and Zane's responses. Any further advise greatly appreciated.

Kind Regards, russ

[Log in to Reply]  [No Email]
soundguy

06-15-2007 12:45:48




Report to Moderator
 Re: Generator in reply to russ b, 06-15-2007 10:28:36  
You didn't indicate that this was a 3rd brush genny.. that adjuster is evidence of it.

Reinstall it with adjuster turned up and see what you get.

soundguy



[Log in to Reply]  [No Email]
russ b

06-15-2007 17:08:49




Report to Moderator
 Re: Generator in reply to soundguy, 06-15-2007 12:45:48  
Soundguy, I put it back on after some more spinnups on the bench.

It is working. The newish battery was not too far down it seems. Giving about 7-8 amps af full throtle according to the gage.

It also appears to try to step up when idled down, then run back up it seems to kick down a bit as speed goes up. Looks like the regulator is working!

How many times have I hooked up a charger over the years. Or, worse left the battery discharged for extended periods.

Many Thanks

*****************

PLUGS, I was having H10s fouling. Installed some H12s recently. I will be monitoring these for a while and trying to get the mix leaned down according to the color.

I just don't use the ol girl like a real farmer. I do some two bottom plowing in a loop, so as to have the plow in the ground half the time. That is the heaviest pulling it sees. FWIW

Kind Regards, russ

[Log in to Reply]  [No Email]
dan hill

06-17-2007 03:50:00




Report to Moderator
 Re: Generator in reply to russ b, 06-15-2007 17:08:49  
H10s are no longer reccommeded for the Ford tractor.H12s are the right heat range.My 600 had h10s when I bought it,much trouble with gas fouling.A set of autolite 437s cured the problem.When you look for new Autolites do not ask for Autolite AL 437 say Autolite 437.The computer and the teenaged clerk wont be able to find them.Champion plugs are made in Mexico now.The shells are breaking off in cylinder heads.Ive had it happen in an olds V8.

[Log in to Reply]  [No Email]
russ b

06-17-2007 10:10:45




Report to Moderator
 Re: Spark Plugs, formerly Generator in reply to dan hill, 06-17-2007 03:50:00  
Thanks for the alert on the Plugs. I will look for the Autolites. I had been using H-10s and idle set rich to boot.

Kind Regards, russ



[Log in to Reply]  [No Email]
ZANE

06-14-2007 17:43:51




Report to Moderator
 Re: Generator in reply to russ b, 06-14-2007 17:13:32  
It would be more likely that the voltage regulator is faulty than the generator. You can put power to the Gen terminal with the Generator ont he tractor and it should motor but this does not necessarily mean it is going to charge.

Zane



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy