Farmall Tractors Discussion Board |
Re: Point Gap Super H vs H
[ View Follow Ups ] [ Post Followup ] [ Return to Farmall Tractors Discussion Board ]
Posted by RKS on May 26, 1999 at 18:09:47 from (152.201.210.194):
In Reply to: Point Gap Super H vs H posted by TomH on May 26, 1999 at 17:55:31:
it's .020 for both the H and super H, for the distributor tractors. It's .013 for both, for the magneto tractors. Also, if you know how and have the equipment, the timing mark is on the crankshaft pulley. If there are two marks, use the first mark (first mark to reach the pointer as the pulley turns is TDC) and set the timing at TDC at low idle, and look for approx 30 degrees advance at high rpm. RKS
Follow Ups: