Posted by Allan on November 15, 2003 at 03:18:43 from (148.63.132.164):
In Reply to: 560 glow plug wiring posted by greg on November 14, 2003 at 17:09:00:
Greg, I can't speak to your particular application, but most all of those old heating systems used 12v glow plugs. And basically, the glow plug was just routed directly to the 12v battery voltage via that manual hold down switch. The gauge circuit was then run in parallel with the plugs to show the operator that the circuit was complete when the button was being held down. The nice part about this old system was that it was almost impossible to "hurt" the glow plugs by holding them on too long. They just kept on heating. Newer systems use a 6v plug which is turned on and off by a solenoid and the 12v feed is then routed thru a 'controller' to the plug. This gives a very fast 'heat-up' time at the plug, but just like a 6v light bulb, the voltage has to be cycled or else that plug will burn itself out since it is being fed 12 volts. In other words, the 6v plugs have to be "pulsed" on and off by that controller. The upshot of this is that if you see a system with all of the glow plugs burned out, the first place to look is to see if someone somewhere has installed the wrong 6v plugs. Very easy to do because a lot of aftermarket partsmen don't catch the difference in a glow plugs' voltage. Now, neither system uses a resistor in the main wiring to the plug that I am aware of. However, there may be a resistor just in that gauge circuit to keep it from being a direct short to ground. But, this would only be in the gauge portion of the circuit. The voltage requirement is stamped on the plug just under the spade or the nut. If yours say 6v and your tractor has a 12v electrical system with a manual "push button" glow plug system, I think your tractor has the wrong glow plugs installed. Hope this helps, Allan
Follow Ups:
Home
| Forums
Today's Featured Article -
The Fordson F Ignition System - by Anthony West. A fellow restorer contacted me earlier this year asking for some help and advice on a model F that he was restoring. He had over a period of months spent a fair amount of his hard earned cash on replacement parts for the old "trembler" ignition. Sadly though all his efforts seemed to be a waste of time and money as he still couldn''t get the temperamental old thing to run correctly!! If i said that this was a little frustrating for him that would be "conservative" in fact the problem had reduce
... [Read Article]
Latest Ad:
1964 I-H 140 tractor with cultivators and sidedresser. Starts and runs good. Asking 2650. CALL RON AT 502-319-1952
[More Ads]
Copyright © 1997-2024 Yesterday's Tractor Co. All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V. Yesterday's Tractors - Antique Tractor HeadquartersWebsite Accessibility Policy |
|