Farmall & IHC Tractors Discussion Board |
Re: More red hot resistor -again
[ Expand ] [ View Follow Ups ] [ Post Followup ] [ Return to Forum ]
Posted by John T on November 24, 2005 at 06:11:29 from (66.244.90.98):
In Reply to: More red hot resistor -again posted by alannpa on November 24, 2005 at 03:45:45:
Good Morning n Hapy Thanksgiving Alan. Myself n Bob n Jim have had fun chewing this over but today were gonna chew on some Turkey later. Thanks for the new tidbit of information. Each time you give us some "new facts" to go on that allows us to add to or modify our answers. If she ONLY heats up when running but NOT otherwise, that lessens to some degree the talk of miswiring as far as a hot battery voltage source being wired/shorted to that Field light switch terminal, cuz if that were the case it should ALWAYS be drawing current. Hmmmmmmmm ?? Soooooooo lets take a look at the differences when running versus not. When running and IFFFFFFFFF the genny has enough Field current??? providing sufficient magentism ??? to produce enough voltage to latch in the Cutout Relay, THEN THE GENNY HAS THE BATTERY PLUS ITSLEF (more ability) WHICH CAN FEED INTO THE FIELD WINDINGS AND LIGTH SWITCH RESISTOR. Without the Cutout Relay being closed, the Field current is more limited to whats being provided by the genny itself WITHOUT the big batterys ability to pump more current through the Fields. THEREFORE it looks like we all need to take a closer look at Jims proposition which was a partial short somewhere in the Fields might be a contributing factor. At first I considered a short "TO GROUND" which would NOT contribute to high field current, while Jim was considering a "windign to winding" short which could. Myself n I think Bon were suspecting a mis wirign somewhere, which may still be a contributign factor. HECK IF I KNOW I guess now the critical thing IFFFFF theres a partial "winding to winding" Field short is where its at. Cuzzzzzz if its a certain kind of short the magnetism will be reduced to the point where the Cutout Relay wouldnt ever latch in (so big battery can feed into a short) but if the short were located at a point that still allowed enough magnetism for the relay to latch in yet still have a path up to the switches resistor it could be pumping extra curent through it causing it to glow. Hmmmmmmmmmmmmmmmm ???????? You know theres another posibility that light switch resistor itslef is bad ??????????????? Thats feasible cuz the genny cant have so bad a field short that its not creating sufficient magnetism to latch the relay in and iffffffff its short aint all that bad,,,,,,,,then I dont see it being a cause for enough excess current to overcurrentg the light switch resistor.. I think for now I still wonder about the wiring or the resistor itself being at fault, cuz I dont feel there could be a field "winding to winding" short bad enough to allow BOTH the relay to latch in PLUS decrease the field winding resistance so much the light switch resistor is over current making her glow. I wonder what the resistance of that light switch resistor is???????? Whether or not the light dimming resistor or it may be cross wired??? I hope Jim n Bob n others toss out more theories here, cuz Im about to run out of smarts lol still thinking more along the lines of a bad switch resistor or miswiring versus a shorted field fer now till we get more info. God Bless yall n Happy Thanksgiving Ol John T in Indiana
Follow Ups:
Home
| Forums
Today's Featured Article -
Talk of the Town: How to Remove a Broken Bolt - by Staff. Another neat discussion from the Tractor Talk Discussion Forum. The discussion started out with the following post: "I have an aluminum steering gear housing with a bolt broken off in it. The bolt is about a 3/8" x 1 1/2" bolt. I've already drilled the center of the bolt out with about 7/64" drill bit the entire length of the bolt. Only one end of the bolt is visible. I tried to use an easy out but it wasn't budging and I didn't want t
... [Read Article]
Latest Ad:
2022 John Deere 5045E, 4wd, front end loader and 3rd function with grapple. 120 hrs, 55k new, must sell
[More Ads]
Copyright © 1997-2024 Yesterday's Tractor Co. All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V. Yesterday's Tractors - Antique Tractor HeadquartersWebsite Accessibility Policy |
|