The Delco regulator has 3 coils. The top coil is connected to the fields, the middle coil, which is made of perhaps 10g wire, is connected to the armature. The botton coil, which is also made of 10g wire goes someplace???perhaps the switch and back to the +12v.
SO MANY QUESTIONS SO LITTLE TIME, here goes hang on,,,,, below is for a Class A system.....
1) The coil/relay that wires to the gennys FLD post is the Field current control relay, its what regulates field current and rate of charge
2) The coil that wires to BAT (has a small winding plus a big outer winding) on the VR that leads up to the Load side of the ammeter that essentially connects (when closed) BAT to GEN/ARM is the CUTOUT RELAY
3) Two Relay/Coil VR's have a combination Voltage and Current control coil while 3 Relay/Coil VR's have a seperate coil for voltage control and a seperaste for current control.
4) BAT on VR to load side of ammeter,,,,GEN/ARM on VR to gennys ARM post,,,,,,,,FLD on VR to Gennys FLD post
5) If VR isnt labeled use an ohm meter: The terminal that reads like an open circuit from it to the case is BAT,,,,,,The terminal that has maybe near 0 or so up to less then 10 ohms is FLD,,,,,,,,the terminal that has maybe 20 to 50 ohms is GEN/ARM.
6) VR wont work unelss well grounded
7) The Genny NOT the VR is what gets polarized. If tractor is staretd and genmy is polarized wrong you can fry the VR
The wiring is a mess. I got the genny to charge by exciting the fields with a 12v tail light bulb.
NOOOOOOOOOOOOOO for max charge on a Class A system you ground the Fields....On a Class B however you full voltage them I CANT SAY SITTIN HERE WHICH YOU HAVE
At an idle the armature showed 13.68 v, however the ammeter is wired backward, it showed discharge.
There is no voltage getting to the fields when the switch is on.
If its a Class A the field needs grounded to work,,,,If its a Class B they do indeed need a voltage input
How should the voltage regulator be wired?
SEE ABOVE
A diagram would be nice, but not necessary. Shouldn"t there be 12v going to the fields when power is applied to the regulator?
YES FOR AN B NO FOR AN A SYSTEM
Should the armature wire be connected two the middle terminal of the regulator?
CANT SAY SITITN HERE, IT SHOULD CONENCT TO ARM ON VR TO ARM ON GENNY, see above to tell which is which
Should the switch power up the bottom terminal of regulator?
If its a 4 terminal VR the GEN/ARM is often off on one side or underneath all by itself. If its a 4 terminal with a LOAD terminal its what feds hot battery voltage up to Ign and Light switches
Work my troubleshootign procedure if its an A system (Most delcos were while some Ford/Autolite and some Massey Harris were B's)
The help provided here and my Troubleshooting procedure require some basic understanding, if youre not familiar at all id take it to a shop before you accidentally fry something
We sell tractor parts! We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]
Today's Featured Article - Usin Your Implements: Bucket Loader - by Curtis Von Fange. Introduction: Dad was raised during the depression years of the thirties. As a kid he worked part time on a farm in Kansas doing many of the manual chores. Some of the more successful farmers of that day had a new time saving device called a tractor. It increased the farm productivity and, in general, made life easier because more work could be done with this 'mechanical beast'. My dad dreamed that some day he would have his own tractor with every implement he could get. When he rea
... [Read Article]
Latest Ad:
2022 John Deere 5045E, 4wd, front end loader and 3rd function with grapple. 120 hrs, 55k new, must sell
[More Ads]
All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy
TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.