Re: ih 504 hydralics
[ View Follow Ups ] [ Post Followup ] [ Return to Tractor Talk ]
Posted by peter on August 11, 1998 at 04:49:18:
In Reply to: ih 504 hydralics posted by jim marshall on August 10, 1998 at 10:44:23:
: I have a 2504 ih boom mower.It has two hyd. pumps a 17gpm THAT FEEDS THE MOWER AND STEERING.THE 7GPM FEEDS THE HITCH WITCH THERE IS NONE CAN THIS PUMP LINE BE tied INTO THE 17GPM LINE TO INCRESE THE POWER Theoretically it should be possible to feed some of the flow from 17 GPM pump into the 7 GPM circuit to supplement the flow. It may cause some priority problems between the two circuits though but i don't think so. You would also have to check the flow capacity of the valves in the 7GPM circuit.Just tee off the 17 GPM circuit after the pump nad feed into 7 GPM circuit between pump and valve. Check valves after the pumps may also be a good idea. Hope this helps.
Follow Ups:
Post a Followup
|