Re: Famall Wiring Nightmare
[ View Follow Ups ] [ Post Followup ] [ Return to Tractor Talk ]
Posted by Gerald on October 15, 1998 at 19:24:36:
In Reply to: Famall Wiring Nightmare posted by Wes on October 15, 1998 at 09:20:50:
: I inheirited a Famall H that was wired strangly. After talking to somebody, this is what I did. : The "Field" from the generator to ground. ( I know that my battery won't charge this way, but right now I'm just trying to get it running) : The "Bat" from the generator to the ammerter. : The Wire from the condensor (It has a magneto) to an "on/off" switch. : That is all of the wiring, now when I ground the battery (Positive ground) the ground wire sparks when I touch the frame, and the generator gets hot, there seems to be juice going to it when it shouldn't be. : If anybody could help me out I would sure appreciate it. : Wes Grounding the field wire probably sets the generator for maximum unregulated output. There's two possible connections and that's one where the field is internally connected to the hot terminal of the generator. You need to wire in a voltage regulator or leave the field terminal OPEN on the generator to not have it charge. I'd vote for a regulator to fit. Gerald