Re: Famall Wiring Nightmare
[ View Follow Ups ] [ Post Followup ] [ Return to Tractor Talk ]
Posted by The Red on October 18, 1998 at 05:33:28:
In Reply to: Famall Wiring Nightmare posted by Wes on October 15, 1998 at 09:20:50:
: I inheirited a Famall H that was wired strangly. After talking to somebody, this is what I did. : The "Field" from the generator to ground. ( I know that my battery won't charge this way, but right now I'm just trying to get it running) : The "Bat" from the generator to the ammerter. : The Wire from the condensor (It has a magneto) to an "on/off" switch. : That is all of the wiring, now when I ground the battery (Positive ground) the ground wire sparks when I touch the frame, and the generator gets hot, there seems to be juice going to it when it shouldn't be. : If anybody could help me out I would sure appreciate it. : Wes Wes, I tried to email you a schematic, but yahoo says you do not exist! If you have the standard light switch, the wire from the gen. field post should go to the resistor screw at the bottom right side of the switch. The wire from the battery post on the voltage regulator should go the right post on the ammeter. The wire from the battery, prob. from the starter switch, should go to the left post on the ammeter. That should be the only wire on that post.
Follow Ups: