Tractor Talk Discussion Board |
Re: '64 Ford 2000 not charging...
[ View Follow Ups ] [ Post Followup ] [ Return to Tractor Talk Discussion Board ]
Posted by John T on March 21, 1999 at 05:30:13:
In Reply to: '64 Ford 2000 not charging... posted by J. Verbeck on March 19, 1999 at 18:01:38:
The Battery terminal on the regulator should always read voltage simply because its connected directly to the battery via and through the ammeter. It gets connected to the generators armature outout only if and when the gen puts out and closes the internal cut out relay otherwise the battery would dischharge when tracor is shut off. So, it sounds like the generators output isnt getting to the battery cause the regulator isnt working. The polarization is the likely cause and Im not sure but think some regulators which are for negative ground only will not work on pos grounds. Try polarizing the regulator and see if it then kicks in. John T in Indiana
Follow Ups: