Walker - Problem could be one of several possible causes: 1 - May be the battery is fully charged and the regulator is simply doing it's job. If a voltmeter is placed across the two battery posts and it indicates 7.2 volts or higher while the ammeter shows 10 amps, there is no problem! 2 - High resistance in the wiring between the generator "A" terminal and the battery. Use an accurate DC voltmeter and take a voltage drop measurement between the generator "A" terminal and the ungrounded battery post with the engine running at full RPM. A reading greater than about 1/4 volt says there's excessive resistance in the circuit. Look for bad connections, undersized wiring, etc. 3 - 3rd brush set to low. Readjust it to it's maximum current position - so 3 commutator bars are showing between the 3rd brush and the nearest fixed brush. Keep in mind most 3 brush tractor generators are only designed for about 14 amps max output. Higher output can cause overheating and damage. 4 - The armature has one or more shorted or open windings. If the generator gets hot to the touch after running about 15 minutes, or if the enamel insulation on the armature windings appears baked/burned, the armature has an internal short. An open winding can be found by probing the commutator with an ohmmeter. Either condition requires rewinding or replacing the armature. 5 - (long shot...) Could be a high resistance ground at the regulator. Note to Pappy - 6 volt IHC tractors built after about 1949 or 1950 use a 3 brush generator with a 2 element voltage regulator in place of a cutout. Pretty sure other tractor builders using Delco electrics did the same.
Follow Ups:
Home
| Forums
Today's Featured Article -
Earthmaster Project Progress Just a little update on my Earthmaster......it's back from the dead! I pulled the head, and soaked the stuck valves with mystery oil overnight, re-installed the head, and bingo, the compression returned. But alas, my carb foiled me again, it would fire a second then flood out. After numerous dead ends for a replacement carb, I went to work fixing mine.I soldered new floats on the float arm, they came from an old motorcycle carb, replaced the packing on the throttle shaft with o-rings, cut new ga
... [Read Article]
Latest Ad:
1964 I-H 140 tractor with cultivators and sidedresser. Starts and runs good. Asking 2650. CALL RON AT 502-319-1952
[More Ads]
Copyright © 1997-2025 Yesterday's Tractor Co. All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V. Yesterday's Tractors - Antique Tractor HeadquartersWebsite Accessibility Policy |
|