Farmall Tractors Discussion Board |
Re: 300 UTILITY HYDROLICS
[ View Follow Ups ] [ Post Followup ] [ Return to Farmall Tractors Discussion Board ]
Posted by George on March 16, 1999 at 20:45:46:
In Reply to: 300 UTILITY HYDROLICS posted by Chuck Kaufman on March 16, 1999 at 19:23:57:
Both the power steering and hitch are low volume systems. the magneto mounted hudraulic pump is not a high volume pump, I would guess 2 or 3 GPM max flow. Most loaders need 8 to 12 GPMs to operate properly. Many of the early loaders used a front mounted crankshaft pump to increase thew folw and volume to speed up loader operations. Good luck George
Follow Ups: