Farmall Tractors Discussion Board |
Re: Re: 6 to 12 volt conversion for 54 H
[ View Follow Ups ] [ Post Followup ] [ Return to Farmall Tractors Discussion Board ]
Posted by RK Smith on April 11, 1999 at 05:11:14:
In Reply to: Re: 6 to 12 volt conversion for 54 H posted by RK Smith on April 11, 1999 at 04:53:53:
In fact, if your tractor runs well now, **don't** monkey with the ignition points, condenser, etc. until you have completed the conversion. I assume you had a generator, so remove the old wires, and if there is a fuse in the old "regulator" in the box with the ammeter (on the steering support post), then pull the fuse out and leave the guts there. Actually, if that thing worked, you may want to preserve it. You never know when you may want to go back to original.
Follow Ups: