Read the electrical code and don't energize the ground system . Don't run neutral current on the ground system. Don't shock the livestock with waters, feeders, stalls and equipment that is elevated above earth potential . Don't be bonding the neutral bar to earth at remote panels. Use four wire to supply services instead of three wire.
FAILED! Not even a slippery diversion, just out right dancing around your wrong statement of, "Neutral does not connect to the water pipe." You either can't read or comprehend the code or just plain dense!
You still are not getting it. The bond to the water pipe, well casing, ground rod etc is with a bare copper wire. The neutral is a white insulated current carrying conductor. You don't know enough about electricity to tell the difference.
You said, ""Neutral does not connect to the water pipe." ". Now I have clearly shown that there is a wire from the neutral bar in the panel (to which neutral connects) to the water pipe. Now if that doesn't connect neutral to the water pipe, pray tell, what the h3!! would it take? A 4x4 copper bar? I don't give a rat's patotie what color you make that wire cover, the fact remains that the neutral conductor coming into that service is in FACT connected to the damn water pipe. Up until now I have given you the benefit of the doubt & humored your obstinate attitude, but finally I'm realizing that you are just simply ignorant! Copper to copper & you claim "no connection". Beyond ignorant, just a plain DA! Everybody else understands the connection & you do too, but are desperately trying, unsuccessfully to save face for the DA statement that, ""Neutral does not connect to the water pipe."
Is neutral current supposed to flow through that bare ground wire from the water pipe to the panel bus bar ?
Current is not supposed to flow thru the ground wire but can if the neutral is messed up between the main breaker panel and the utility company's transformer.
Lets take this thread out of neutral and put it in drive?
This post was edited by IH2444 at 16:29:24 11/07/13.
We sell tractor parts! We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]
Today's Featured Article - Restoration Story: Fordson Major - by Anthony West. George bought his Fordson Major from a an implement sale about 18 years ago for £200.00 (UK). There is no known history regarding its origins or what service it had done, but the following work was undertaken alone to bring it up to show standard. From the engine number, it was found that this Major was produced late 1946. It was almost complete but had various parts that would definitely need replacing.
... [Read Article]
Latest Ad:
1964 I-H 140 tractor with cultivators and sidedresser. Starts and runs good. Asking 2650. CALL RON AT 502-319-1952
[More Ads]
All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy
TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.