Posted by BlakeinTN on June 08, 2008 at 10:05:20 from (66.38.116.245):
Went out and started the tractor yesterday, and the little AMP light came on. Battery voltage with the tractor running is 12.4, but I'm having problems checking my generator output.
When I put my negative meter lead on the negative battery terminal, and touch the positive meter lead to either of the two poles on the generator, I get 0. When I stick the negative meter lead on the positive battery terminal, and the positive meter lead on either of the generator posts, I get -12.4
Where do I need to check next, or what should I be looking for? Thanks!
We sell tractor parts! We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]
Today's Featured Article - Hydraulic Basics - Part 2 - by Curtis Von Fange. In the last entry to this series we gave a brief overview of hydraulic system theory, its basic components and how it works. Now lets take a look at some general maintenance tips that will keep our system operating to its fullest potential. The two biggest enemies to a hydraulic system are dirt and water. Dirt can score the insides of cylinders, spool valves and pumps. Wate
... [Read Article]
Latest Ad:
1964 I-H 140 tractor with cultivators and sidedresser. Starts and runs good. Asking 2650. CALL RON AT 502-319-1952
[More Ads]
All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy
TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.